Buying a Home Inverter and Battery: Sizing It Properly

On: November 5, 2026 |
Follow Us:
Inverter Buying

A family buys an inverter after a bad summer, is sold a package by the shop’s recommendation, and discovers that it runs four lights and two fans for about ninety minutes. They wanted the refrigerator on it too, and the television, and three hours of backup.

Nothing was defective. The unit was sized by what fitted the budget rather than by what the house needed, which is how most inverters in India are sold. The calculation that avoids this takes five minutes and two formulas.

Product specifications, prices, warranty terms and subsidy schemes change. Verify current details and ratings before buying.

First, what you are actually buying

  • A home inverter with a battery — what most people want. It charges from the mains, switches over when power fails, and runs lights, fans, a television and similar loads for hours.
  • A computer UPS — a different product, giving minutes rather than hours, intended to let a computer shut down safely. Do not buy one for household backup.
  • A solar or hybrid inverter, which can charge from panels as well as the grid.

Shops often call home inverters “home UPS”, which muddles the two. Judge by the battery capacity and the stated backup, not the label.

The two calculations

Working out the size
Working out the size

Step one: the inverter’s capacity.

Add up the wattage of everything you want running at once. Rough figures to work with, which you should check against your own appliances:

  • An LED bulb, under ten watts.
  • An ordinary ceiling fan, around seventy to eighty watts. A modern energy-efficient fan, around thirty.
  • A television, roughly a hundred watts depending on size.
  • A laptop charger, around sixty-five watts; a router, around ten.
  • A refrigerator, perhaps a hundred and fifty to two hundred watts while running — but several times that for the instant the compressor starts.
  • A mixer or a water pump, several hundred watts, again with a large starting surge.

Say you arrive at four hundred watts. Inverters are rated in volt-amperes rather than watts, so divide the wattage by about 0.8 to get the VA requirement — five hundred in this case — and then add roughly a quarter as headroom for starting surges and for the appliance you will inevitably add later. So a six hundred VA unit or the next standard size up.

Step two: the battery capacity.

Multiply the load in watts by the hours of backup you want, then divide by the battery voltage multiplied by about 0.8 for losses.

Four hundred watts for three hours, on a twelve volt system: four hundred times three, divided by twelve times 0.8, which comes to roughly a hundred and twenty-five ampere-hours. Round up to the next standard size.

Longer backup or a heavier load pushes you to a twenty-four volt system with two batteries, which is more efficient at higher loads.

Do this arithmetic at home. A shop asked for “a good inverter” will quote by price point.

Pure sine wave, which matters more than the brand

Inverters produce either a pure sine wave output, like the mains, or a square or modified wave, which is a cheaper approximation.

Square wave units cost less and are a false economy. On a square wave output, fans hum and run slightly hot, tube lights and some LED drivers buzz, electronics with switching power supplies run less efficiently, and anything with a motor — a refrigerator, a water pump, a mixer — is stressed. Over years this shortens the life of the appliances you bought the inverter to keep running.

Buy pure sine wave. If a quotation does not say so explicitly, assume it is not, and ask. This single specification matters more than the brand on the box.

What not to run on it

  • Air conditioners, except on a large and expensive purpose-built system. A standard home inverter will not do it.
  • Water heaters, geysers, induction cooktops, electric kettles and irons. These are heating loads of one to two kilowatts and will flatten any ordinary battery bank in minutes.
  • A refrigerator, unless you sized for it. It is possible, and it needs capacity for the compressor’s starting surge, not just its running wattage. Tell the dealer explicitly if the fridge is to be included, and size for the surge.
  • Water pumps, for the same surge reason.

Be realistic about this rather than hopeful. An inverter that runs lights, fans, the television, the router and phone chargers through a long cut is doing the job people actually need.

Choosing the battery

Which battery, and for what
Which battery, and for what

The battery is most of the cost, most of the weight, and the part that wears out.

Flat plate batteries are the cheapest and have the shortest life. They suit areas with short, frequent cuts where the battery is rarely deeply discharged.

Tubular batteries cost noticeably more and last considerably longer, and they tolerate deep discharge far better. For most Indian homes with long power cuts, this is the right choice, and the cost per year of life is lower than flat plate despite the higher price.

Sealed maintenance-free batteries need no water topping up, which is genuinely convenient, at a higher cost per unit of capacity and generally a shorter life.

Lithium systems cost several times as much, last several times as long, need no maintenance, weigh a fraction as much, tolerate partial charging, and recover faster. Over a full life the total cost can work out comparable or better. Check the warranty terms and the service network carefully, because this is a newer segment.

Two practical checks whichever you buy:

Compare cost per year of expected life, not the price on the box. A battery costing fifty per cent more and lasting twice as long is the cheaper purchase.

Check the manufacture date stamped on the battery. Lead-acid batteries degrade while sitting in a warehouse, and a unit manufactured many months ago has already lost some of its life. Ask for a recent one; this is a reasonable request and dealers accommodate it.

Installation

  • A ventilated location, not a bedroom or a closed cupboard. Conventional lead-acid batteries release hydrogen while charging, which must disperse. A balcony, a utility area or a well-ventilated corner is right; a sealed box under a bed is not.
  • On a trolley or stand, off the floor, out of children’s reach, away from damp.
  • Proper earthing and correctly rated wiring, installed by a qualified electrician.
  • Decide the circuits it feeds. Wiring selected circuits — the lights, the fans, one socket per room, the router — rather than the whole house prevents someone plugging a geyser into an inverter-backed socket.
  • Label the inverter-backed sockets, which is cheap and saves arguments.
  • Keep the inverter itself ventilated too, since it generates heat.

Maintenance and running cost

  1. Distilled water only, for a conventional lead-acid battery. Tap water contains minerals that destroy the plates. This is the commonest way people kill a good battery.
  2. Check the electrolyte level every two or three months and top up to the marked level. Do not overfill.
  3. Keep the terminals clean and lightly coated with petroleum jelly to prevent corrosion.
  4. Discharge it occasionally if you have long spells without power cuts — a battery that is never cycled deteriorates too. Many inverters have a setting for this.
  5. Expect to pay for charging losses. Charging and discharging loses a meaningful share of the energy, commonly around a fifth to a third, so the unit consumes more electricity than it delivers. That is the cost of having backup.
  6. Read the warranty carefully. Many battery warranties are full replacement for an initial period and then pro-rata, meaning a failure in year three gets you a partial credit rather than a new battery. Know which you have bought.
  7. Dispose of the old battery properly. Lead-acid batteries are regulated waste and must go to authorised collection or recycling, usually through the dealer on exchange. Do not sell it to an informal scrap buyer.

Solar, if you are planning ahead

A solar panel array can charge the same battery bank, which turns a backup system into something that also reduces your electricity bill. There are government schemes for rooftop solar for residential consumers, with subsidy support and net metering arrangements that vary by state and by eligibility.

If solar is a possibility within a few years, buy a solar-ready or hybrid inverter now rather than replacing the unit later, and size the battery bank with that in mind. Check the current scheme terms and your state distribution company’s net metering rules before committing, because the economics depend heavily on both.

Frequently asked questions

How do I work out what size inverter I need?

Add the wattage of everything you want running at once, divide by about 0.8 to get the volt-ampere rating, then add roughly a quarter as headroom. For the battery, multiply the load in watts by the hours of backup and divide by the battery voltage times 0.8 to get ampere-hours.

Pure sine wave or square wave?

Pure sine wave, always. Square wave output makes fans hum and run hot, buzzes in lights, and stresses anything with a motor or a switching power supply — shortening the life of the appliances you bought the inverter to protect.

Can I run my refrigerator or air conditioner on it?

A refrigerator is possible if you sized for the compressor’s starting surge, not just its running wattage — say so explicitly when buying. An air conditioner needs a large purpose-built system, as do geysers, induction cooktops and water pumps.

Which battery type should I choose?

Tubular for most Indian homes with long power cuts, because it tolerates deep discharge and lasts far longer than flat plate. Compare cost per year of expected life rather than the purchase price, and check the manufacture date stamped on the battery.

Where should the battery be kept?

Somewhere ventilated — a balcony or utility area, on a trolley, off the floor and away from children. Not in a bedroom or a sealed cupboard, since conventional lead-acid batteries release hydrogen while charging.

What kills a battery fastest?

Topping it up with tap water instead of distilled water. After that: never checking the electrolyte level, letting terminals corrode, and keeping it in an unventilated space.

In short

Size it yourself before you walk into a shop. Add the watts you want running, divide by about 0.8 and add a quarter for the inverter rating; multiply watts by hours and divide by battery voltage times 0.8 for the ampere-hours. Four hundred watts for three hours needs roughly a 125 ampere-hour battery.

Then insist on pure sine wave, which matters more than the brand, because square wave output quietly damages the fans, electronics and motors you bought the backup for. Be honest about what it will not run — air conditioners, geysers, induction cooktops, pumps — and if the refrigerator is to be included, size for the compressor’s starting surge and say so when buying.

Choose tubular batteries for long power cuts, compare cost per year of life rather than the sticker price, check the manufacture date, and read whether the warranty is full replacement or pro-rata. Install it somewhere ventilated on a trolley, wire selected circuits rather than the whole house, top up only with distilled water, and dispose of the old battery through authorised channels. And if rooftop solar is a possibility in the next few years, buy a hybrid inverter now rather than replacing it later.

यह भी पढ़िए: Buying an Air Conditioner in India: Tonnage, Inverter and the Running Cost · Fixing Slow WiFi at Home: What Actually Causes It · Buying a Refrigerator in India: Capacity, Door Type and Running Cost